High-Precision Gas and Vapor Adsorption Analyzer Seria BELSORP MAX X

A lot of Science in a little space: BELSORP MAX X. High-End Adsorption. Smallest Footprint. Unrivaled Performance.

Microtrac's BELSORP MAX X is the latest model in the BELSORP MAX series, featuring a more compact design and lower weight. This high-precision gas / vapor adsorption analyzer can measure up to four samples over a wide range of pressures and temperatures. BELSORP MAX X covers a broad array of analysis capabilities from specific surface area, pore size distribution, gas, and vapor adsorption to chemisorption.

Combining high-precision pressure transducers (133.3 kPa, 1.333 kPa, and 0.0133 kPa) with hard-sealing pneumatic valves and metal gaskets, the analyzer has superior technology to minimize gas leakage and enable ultimate vacuum levels. Temperature in the BELSORP MAX X is carefully controlled using state-of-the-art technology, from the heated manifold block (50 °C, optional 80 °C) and air bath to the sample, while electropolished gas / vapor lines prevent surface wetting and corrosion.

Additionally, the new BELCONTROL operation software facilitates understanding of the structure and durability of materials through cyclical stability analysis, improves measurement and maintenance efficiency, and sends measurement results via e-mail – all resulting in maxXimized sample throughput. BELMASTER is the dedicated analysis software for advanced material evaluations. This instrument complies with ISO 9277, 15901-2 and 18852 and can be used for various material morphologies, such as molded bodies, pellets, and fine powders.

BELSORP Series

State-Of-The-Art Technology in the Smallest Space MaxXimize Your Lab Space


MaxXimize your lab space by minimizing the footprint! The required lab space is reduced by almost 50% compared to alternative products.

Easy Data Management & More Quality Insights MaxXimize Your Accuracy

AFSMTM: Highest Reproducibility Available on Any Adsorption Instrument

Rather than attempting to control the approximate level of liquid coolant, our innovative method of continuously monitoring free space variations in a reference cell – Advanced Free Space Measurement (AFSMTM) – has been proven to provide greater measurement accuracy. It accurately compensates for free space fluctuations due to environmental factors such as:

  • Changes in LN2 level
  • Changes in temperature and pressure in the atmosphere
  • Changes in coolant temperature due to dissolution of oxygen

Vapor Adsorption Option

Inside the BELSORP MAX X, all gas lines, gauges, etc. are installed in a thermostatic air chamber (50 °C) covered with thermally insulating material. The fully temperature-controlled instrument prevents vapor condensation effects and allows various vapor adsorption measurements to be made. It includes measurements with organic vapors up to 40 °C (standard instrument; HT model up to 70 °C). The evaluation of hydrophilicity / hydrophobicity and the measurement of VOC adsorption capacity are further application possibilities.

 

Fully Customizable & Upgradeable Maxximize Your Flexibility


Extensive Product Range

BELSORP MAX X is available in different models for a wide range of applications. Microtrac offers the perfect solution for each customer's individual needs.

Gas Selector for Different Adsorbents

Three gas ports (corrosion resistant) are available in the standard configuration. To expand one standard line to four gas lines, a gas seector can be addded. The gas lines can be expanded from 3 to 6, 9 and 12 lines.

Measurement Temperature Control

Deware (ciecz kriogeniczna), kąpieli wodne (-10°C do 80°C) i grzejniki (50°C do 550°C) są dostępne, obejmując szeroki zakres temperatur pomiarowych. Grzejnik można wykorzystać zarówno do pomiarów, jak i do przygotowania próbek.

Opcjonalna kontrola temperatury kriogenicznej BELCRYO X

Ulepsz swoje pomiary adsorpcji za pomocą BELCRYO X, systemu kriostatu o precyzyjnej kontroli, zaprojektowanego do płynnej integracji z serią BELSORP.

Rozszerzając kontrolę temperatury z 50 K do 473 K (-223°C do 200°C), BELCRYO X umożliwia wysoce stabilne i powtarzalne pomiary w szerokim zakresie warunków eksperymentalnych – bez potrzeby użycia ciekłego azotu. Dzięki temu jest idealny do zaawansowanych badań, takich jak analiza powierzchni BET, rozkład wielkości porów, magazynowanie gazu i badania nad separacją gazów.

Połączenie z BELSORP MAX X / MAX G pozwala na wykorzystanie BELCRYO X do:

  • Dokładnych pomiarów izoterm adsorpcji w wielu temperaturach
  • Niezawodnej oceny izosterycznego ciepła adsorpcji
  • Rozszerzonych możliwości badań nad kriogenicznym magazynowaniem i separacją gazów
  • Pełnie sterowanej oprogramowaniem i zautomatyzowanej pracy za pomocą oprogramowania BELControl

Special Models of the BELSORP MAX X Series


BELSORP MAX X HT

The BELSORP MAX X HT is a special model enabling various types of vapor adsorption (water vapor, VOCs, and more) at higher temperatures than the regular version. The manifold block can be heated up to 80°C, enabling a wider application range under more realistic conditions. The instruments is used in application fields such as:

  • Cement, concrete and building materials
  • Heat transformation / air conditioning
  • Electrode battery (LiB) & GDL fuel cells

BELSORP MAX X HP

The BELSORP MAX X HP has been added as a custom solution to the BELSORP MAX X product line to enable gas adsorption, BET surface area, pore size distribution, vapor adsorption, and the evaluation of adsorption rates at high pressure up to 900 kPa. The instrument is used in application fields like:

  • Efficient utilization of CO2
  • Energy storage (CH4 / CH3C6H11 / H2)
  • Heat pumps
  • Air separation material used in PSA / TSA

Simultaneous Measurement of up to 4 Samples MaxXimize Your Throughput

BELSORP MAX X offers four independent ports and one dedicated port for saturated vapor pressure measurement. Up to three ports are equippable with a unique set of pressure transducers (0.0133 kPa, 1.33 kPa, 133.3 kPa) for better micropore analyses, allowing fully independent and simultaneous measurements over a wide range. Two measurement modes can be selected depending on the application. The High Precision Mode and the Multi-sample Mode are both available for measurements starting at lowest relative pressure P/P0 = ~10-9.

 

Analizator Powierzchni i Rozkładu Wielkości Porów BELSORP MAX X Quality & Reproducibility


Quality & Reproducibility

The high-precision mode allows the simultaneous acquisition of adsorption / desorption isotherms for up to three samples. The fourth port uses an empty sample cell as a reference for the precise measurement of free space/dead volume changes (patented AFSMTM technology). In addition, a special port allows accurate measurement of the saturation vapor pressure at any time. This mode is recommended for research and development purposes, e.g. for evaluating small sample volumes in material development.

Multi-Sample Mode

The multi-sample mode allows the user to obtain adsorption / desorption isotherms of up to four samples simultaneously, while the saturation vapor pressure is determined at any time via a dedicated port. Unlike the high precision mode, the calculation of the free space change in the sample tube is based on a pre-loaded measurement file. This mode is recommended for applications such as quality control, when samples were already characterized in large quantities.

Reduction of Measurement Time

The two following features reduce the measurement time by about 50-70%:


Gas Dosing Optimization

By uploading a previously measured adsorption isotherm, the optimum measurement conditions for the samples are automatically determined. Each measuring point can be conveniently added or deleted, allowing the user to easily determine the gas injection quantity.

1. Load an existing isotherm | 2. Display of expected isotherm | 3. Input of measurement range | 4. Automatic optimization of conditions such as gas introduction volume |


Feedback Control of Gas Inlet Valve

By determining the gas inlet pressure according to the installation environment (secondary pressure of the gas cylinder) before measurement, the control valve is automatically optimized for speed and performance, successfully reducing the measurement time.

Support of a Wide Range of Adsorbents & Measurement Conditions

Various gas and vapor adsorption measurements are possible. With dedicated accessories, a wide temperature range can be maintained during analysis or pre-treatment.

  • N2 / Ar evaluation of specific surface area and pore distribution by adsorption measurements from very low to high relative pressures
  • CO2 ultra-micropore evaluation by adsorption measurements up to high pressures (optional)
  • Evaluation of low specific surface areas by Kr adsorption measurements
  • Adsorption measurement of NH3, H2, CO2, O2, CH4 and other non-corrosive gases
  • Evaluation of hydrophilicity and hydrophobicity by water vapor adsorption measurement
  • Adsorption measurement of alcohol, benzene, and other non-corrosive vapors (VOCs)
  • Measurement of adsorption rate of various gases and vapors (kinetic analysis)

Suitable for Measuring Materials of Different Shapes

Measurements can be made on a variety of materials, including pellets, molds, substrates, as well as powders and other materials that should not be exposed to the atmosphere. The connector is equipped with a sample tube with an outer diameter of φ9 mm or φ14 mm. Special sample tubes can be provided for larger samples, such as pellets, and smaller fine powder samples can also be easily measured with the appropriate sample tubes.

More BELCONTROL Features

  • Overlaying adsorption / desorption isotherms and comparing the measured data between the various ports during measurement
  • All pressures, temperatures, valve actuations, etc. are stored in trend data, allowing for immediate examination
  • A system check function is available for diagnosing the instrument status
  • E-mail notification automatically transmits measurement status and results
  • Interactive program in Japanese or English ensures easy, reliable operation
  • Extensive help functions, including step-by-step instructions during operation

Analizator Powierzchni i Rozkładu Wielkości Porów BELSORP MAX X Dodatkowe opcje i akcesoria

Standard Accessories
The BELSORP MAX X is delivered with a wide range of standard accessories like Dewar vessel, thermal insulation cover / sleeve, P0 tube, sample cells, glass rods, sample funnel, sample cell holders, sample scattering prevention filter, reference sample, O-rings and more.

Extensive Product Line-up
Various models are available for a variety of gas and vapor adsorption measurements. Microtrac proposes the most suitable model by combining pressure sensors according to the number of samples and pore distribution evaluation range.

System pomiarowy AirGuard
System pomiarowy AirGuard umożliwia dokładną analizę powierzchni BET i rozkładu wielkości porów na instrumentach BELSORP, jednocześnie chroniąc wrażliwe próbki przed kontaktem z wilgocią i tlenem. Jest to szczególnie ważne dla materiałów funkcjonalnych, które mogą reagować z powietrzem, potencjalnie zmieniając ich strukturę lub generując gazy korozyjne.

Dzięki prostemu montażowi jednym dotknięciem, AirGuard zapewnia pomiary o wysokiej precyzji bez wydłużania czasu analizy. Jest to przystępna cenowo modernizacja, którą można również zamontować w istniejących systemach BELSORP, umożliwiając niezawodną analizę wolną od zanieczyszczeń.

Analizator Powierzchni i Rozkładu Wielkości Porów BELCONTROL: New Operation Software

The versatility of BELSORP equipment is truly world leading. The numerous features and capabilities are complemented by BELCONTROL the intuitive and user-friendly operation software. It guides the user step-by-step through the analysis process. This includes the setup of analysis conditions, executing the measurements, when to fill and setup the liquid nitrogen or other bath, when to replace the gas cylinder, the degassing steps, and much more. The software is designed to make the instrument accessible and operable to everyone, including inexperienced users.

For inexperienced users or for measurements of unknown samples, BELCONTROL only requires basic sample information (name, mass, etc.), pre-treatment conditions (if not performed externally) and the measurement range.

Detailed control of the configuration and measurement settings is possible to optimize the measurement conditions (e.g. dosing settings, equilibrium criteria, leak test option, etc.). This allows the user to fully customize the sample analysis to his needs.


BELCONTROL
Quick BET tak Multi-point BET surface area in less than 20 minutes
Helium-Free Measurement tak AFSMTM 2 enables He-free measurements with unmatched accuracy
Adsorption Kinetics opcjonalnie Rate of adsorption measurements for diffusion analysis

Analizator Powierzchni i Rozkładu Wielkości Porów BELSORP MAX X BELMASTER Analysis Software

Dane można analizować za pomocą przeciągania i upuszczania. Nakładanie wykresów, skalowanie osi X-Y, konwersja jednostek, znaczniki punktów i kolory można łatwo zmieniać. Kolor można ustawić dla poszczególnych danych, aby poprawić widoczność tych samych danych w różnych typach analiz. Ekran z wynikami analizy można zapisać. Nawet jeśli komputer zostanie wyłączony, analizę można powtórzyć z zapisanego stanu po ponownym uruchomieniu komputera. Wyniki analizy można łatwo przekonwertować do formatu MS Excel za pomocą przeciągania i upuszczania. Funkcja rutynowego ustawiania analizy jest przydatna, gdy wykonuje się tę samą analizę wielokrotnie. Dane zdefiniowane przez użytkownika można zapisać jako izotermy referencyjne do analizy rozkładu porów, t-plot i $\alpha$s. Wszystkie operacje można wyświetlić jednym kliknięciem prawym przyciskiem myszy. Oprogramowanie BELSIM (QSDFT / NLDFT / GCMC) do analizy rozkładu porów za pomocą symulacji jest w zestawie. Łatwa konwersja do MS Excel odbywa się jednym kliknięciem myszy.


BELMASTER Software

BELMASTER Analysis Programs

  • Adsorption / desorption isotherm
  • PCT curve
  • BET specific surface area and Type I (ISO9277) BET automated analysis
  • Langmuir specific surface area
  • BJH, DH, CI, and INNES methods (mesopore distribution)
  • HK, SF and CY methods (micropore distribution)
  • t-plot method (micro to mesopore analysis)
  • αs plot method (micro- to mesopore analysis)
  • MP method (micropore distribution)
  • Dubinin-Astakhov method (micropore volume)
  • Equivariant differential heat of adsorption
  • Differential adsorption isotherm
  • Fractal dimension
  • Molecular probe method (ultra-micropore analysis)
  • Adsorption rate analysis
  • QSDFT / NLDFT / GCMC (rozkład mikro do mezopory / makropory)

Microtrac dostarcza analizę rozkładu wielkości porów nowej generacji za pomocą zaawansowanych metod QSDFT, NLDFT i GCMC, przezwyciężając ograniczenia tradycyjnych podejść, umożliwiając zunifikowaną, precyzyjną charakterystykę w szerokim zakresie wielkości porów od 0,35 do 500 nm. W połączeniu z serią BELSORP do dokładnych pomiarów izoterm adsorpcji, to rozwiązanie zapewnia niezawodną i wydajną ocenę struktur porowych. BELMaster posiada rozbudowaną bibliotekę 59 jąder dla gazów takich jak N₂, Ar i CO₂, umożliwiającą dostosowaną analizę poprzez uwzględnianie właściwości powierzchni materiału i kształtów porów dla konkretnych typów materiałów (zeolity, metoporowata krzemionka, węgiel aktywny i inne).

Analizator Powierzchni i Rozkładu Wielkości Porów BELSORP MAX X Przykłady pomiarów


Nitrogen adsorption measurements at 77K of activated carbon fibre (black), MCM-41 (blue), metal-organic framework MIL-160 (orange) and PdC catalyst (red)

Logaritmic scaled nitrogen adsorption measurements at 77K of activated carbon fibre (black), zeolite MCM-41 (blue), metal-organic framework MIL-160 (orange) and PdC catalyst (red)

Water sorption measurements of metal-organic framework UiO-66 at 25 °C (red) and 40 °C (black)

Various vapor adsorption measurements of activated carbon fibre H2O at 20 °C (red), CH3OH at 15 °C (blue), C6H6 at 20 °C(green), and CCl4 at 20 °C (orange)

Analizator Powierzchni i Rozkładu Wielkości Porów BELSORP MAX X Typowe aplikacje


BELSORP MAX X can be used in a wide range of applications including catalysts, batteries, fibers, polymer materials, pharmaceuticals, pigments, cosmetics, magnetic powders, separation membranes, filters, toners, cement, ceramics, and semiconductor materials.

Aby znaleźć najlepsze rozwiązanie dla swoich potrzeb w zakresie charakterystyki cząstek, odwiedź naszą bazę danych aplikacji.

Teaser Max X

High-Precision Gas and Vapor Adsorption Analyzer Seria BELSORP MAX X Dane techniczne

Zasada pomiaru Manometric method (volumetric method) + AFSM™ or AFSM™2
Adsorbaty - gazy N2, Ar, CO2, H2, Kr, O2, NH3, NO, CO, CH4, C2H6, C3H8, n-C4H10, iso-C4H10 i inne (nie-) gazy korozyjne
Adsorbaty - pary H2O/woda, C6H6/benzen, C6H5CH3/toluen, CH3OH/metanol, C2H5OH/etanol, n-C5H12/n-pentan, n-C6H14/n-hexan, c-C6sub
Porty do podłączania gazów 3 ports (optional: up to 12 ports)
Liczba pomiarów MAX X: max. 4 ports simultaneously
MAX X-HT: max. 4 ports simultaneously
MAXX-HP: max. 3 ports simultaneously
Zakres pomiarowy (powierzchnia właściwa) 0,01 m2/g i więcej (N2)
0,0005 m2/g i więcej (Kr)
(w zależności od gęstości próbki)
Measurement range (pore size distribution) 0,35 - 500 nm
Measurement range (gas adsorption isotherm) MAX X: P/P0 = 10-8~~0.997 (N2@77.4K, Ar@87.3K)
MAX X-HT: max. P/P0 = 10-6~~0.997 (N2@77.4K, Ar@87.3K)
MAXX-HP: P/P0 = 10-8~~0.997 (N2@77.4K, Ar@87.3K)
Measurement range (vapor adsorption isotherm) MAX X: P/P0 = ~0.95 @40°C
MAX X-HT: P/P0 = ~0.95 @80°C
MAXX-HP: P/P0 = ~0.95 @40°C
Measurement range (high pressure gas adsorption isotherm) MAX X: -
MAX X-HT: -
MAXX-HP: 10Pa~900kPa
Pressure transducer (1MPa: 7500 Torr) MAX X: -
MAX X-HT: -
MAXX-HP: 1 unit
Przetwornik ciśnienia (133 kPa: 1000 Tr) MAX X: 6 units
MAX X-HT: 6 units
MAXX-HP: 5 units
Przetwornik ciśnienia (1.33 kPa: 10 Tr) MAX X: max. 4 units
MAX X-HT: 4 units
MAXX-HP: 3 units
Przetwornik ciśnienia (0.0133 kPa: 0,1 Tr) MAX X: max. 3 units
MAX X-HT: -
MAXX-HP: 2 units
Termostatyczny piec powietrzny MAX X: 50°C
MAX X-HT: 80°C
MAXX-HP: 50°C
Vacuum gauge / pump Cold cathode gage (Optional)/Turbo molecular pump + rotary pump (or diaphragm pump)
Measurement temperature (Dewar vessel) LN2, temperatura LAr; Czas trwania: 80 h
Measurement temperature (Pretreatment heater) 50 - 550°C
Measurement temperature (Water bath) -10 - 80°C (constant temperature circulator)
Wymiary (szer. x wys. x gł.) 360 x 870 x 590 mm
Masa (aparat podstawowy) 50 kg
Użytkowanie - gaz He, adsorption gas pressure: 0.1MPa (G)
Joint: 1/8" Swagelok joint
Valve operan gas pressure: 0.5 - 0.6 Mpa (G)
Joint: 1/4" one-touch pipe contact
Użytkowanie - zasilanie AC 100 - 240 V / 400 W (pompa rotacyjna nie wchodzi w skład zestawu)
Certyfikat CE tak
Operating software Windows 10 operating system or higher, CPU Intel(R) Core i5 or higher
2 GB of memory or more, 5 GB HDD space or more
Zalecany monitor Monitory Full HD

High-Precision Gas and Vapor Adsorption Analyzer Seria BELSORP MAX X Do pobrania

Wyświetlanie wyników 1 - 6 z 43
Resetuj wszystkie filtry